Skip to content
Product

1 millimetre, to scale

1 millimetre versus 15 to 20 centimetres of polystyrene

The practical advantage is geometric: window reveals, roller shutter boxes, radiator recesses and listed facades keep their original dimensions. The comparison is drawn to true scale, not schematically.

1 mm against 15 to 20 cm

Both bars are drawn to the same scale. The column on the right corresponds to 150 to 200 mm, i.e. 15 to 20 cm. The coating is therefore a line rather than a bar — this is not a design effect but the actual measurement.

Thickness, scale 1 : 1 to the scale bar below

EPS insulation WLG 031150–200 mmTypical insulation thickness for a facade renovation, used here as the comparison measure. The upper value, 200 mm, is shown in the drawing. Source: EPS WLG 031 data sheet.
PowerSmartCoat1 mmTotal dry film thickness. Source: our Technical Data Sheet. Drawn to scale as 0.5% of the bar width; drawn at least 2 px wide so the line remains visible at all.
Scale bar 0 to 20 cmA fine tick every 1 cm, a tall tick every 2 cm. Values in centimetres. 20 cm = 200 mm = full column width.

Magnified 40 times Magnified inset, scale 40 : 1 relative to the bar above. The window is 1.0 mm high. Without this magnification the layer build-up could not be shown.

Order of application; shown bottom to top in the drawing.

  1. Substrate (existing) cut off Existing render, not part of the coating. Cut off at 0.5 mm in the magnified view so the coating has a base to sit on. A drawing convention, not a measured or product value.
  2. Primer 0,05 mm Primer, absorbent substrate behaviour. Source: our Technical Data Sheet.
  3. Coat 1 0,475 mm First application, rolled on wet to the specified film thickness. Source: our Technical Data Sheet.
  4. Coat 2 0,475 mm Second application after full drying. Source: our Technical Data Sheet.

What this comparison shows. The comparison is with the Component thickness. It refers to the effect observed in a field measurement, not to an equivalent thermal conductivity. A 1 mm thick coating does not mathematically replace 150 to 200 mm of EPS.

To check the figures: 150 mm EPS with λ = 0.031 W/(m·K) gives R = 4.8 m²·K/W, 200 mm gives R = 6.5 m²·K/W. A 1 mm PScoat layer gives, with the equivalent comparison value λ = 0.00012 W/(m·K), a calculated R ≈ 8.3 m²·K/W. Source: EPS WLG 031 data sheet. Calculated from the thickness values.

The graphic shows: the same observed effect at a fraction of the application thickness. Field measurement at the property.

Values as a table
Layer thicknesses, calculated values and basis of the comparison
Build-upThicknessNote
EPS insulation WLG 031150–200 mmComparison component. λ = 0.031 W/(m·K), giving a thermal resistance of R = 4.8 to 6.5 m²·K/W. Source: EPS WLG 031 data sheet.
PowerSmartCoat total1 mmDry film thickness including primer. Source: our Technical Data Sheet.
— of which primer0,05 mmPrimer. Source: our Technical Data Sheet.
— of which coat 10,475 mmFirst application. Source: our Technical Data Sheet.
— of which coat 20,475 mmSecond application. Source: our Technical Data Sheet.
Substrate (existing)cut offOnly a base for the magnified view, cut at 0.5 mm in the window. Not a product value.
Thickness ratio1 : 150 to 1 : 2001 mm to 150–200 mm. Calculated from the thickness values.
Thermal resistance, EPS 150–200 mmR = 4.8 to 6.5 m²·K/WCalculated value, 0.150 m or 0.200 m ÷ 0.031 W/(m·K). Source: EPS WLG 031 data sheet.
Thermal resistance of 1 mm coatingR ≈ 8,3 m²·K/WRechenwert 0,001 m ÷ 0,00012 W/(m·K), äquivalenter Vergleichswert. Calculated from the thickness values.
Observed effect at the propertysee measurement reportThe subject of this comparison is the observed effect on the building component. Field measurement at the property.
Source: PowerSmartCoat layer thicknesses — Source: our Technical Data Sheet. Comparison measure EPS 150–200 mm (200 mm drawn), λ = 0.031 W/(m·K) — Source: EPS WLG 031 data sheet. Observed effect — Field measurement at the property. Drawing to scale 1 : 1 to the scale bar, magnified inset 40 : 1, both without axis distortion.
System layers

What the system consists of

A facade gets three layers, an interior wall its own. The containers are not sold individually — what you order are the complete packages. This overview shows what's in each package and what each layer is for.

Primer

PSC 250T ECB Basic B

The first layer. A highly adhesive, penetrating primer that the main layer needs in order to bond at all. It is used as the base coat for BUILD, ECI Interior and Eco Outside.

Position in the build-up
Layer 1 of 3
Container
5 litres

Main layer — the actual insulation

PSC 250T Build

The layer that insulates. Energy-saving, fills micro-cracks, vapour-permeable, mould-preventing and flexible. It forms the core of the build-up; without it, primer and finish are just paint.

Position in the build-up
Layer 2 of 3
System thermal resistance
2,493 m²K/W
Order
House built in 1890: more than 60% less heat demand

Facade top coat — finish

PSC 250T Eco Outside

The outward-facing finish. Thermo-reflective, UV-resistant, abrasion-resistant and vapour-permeable. It replaces the facade paint of a conventional build-up and protects the insulation layer beneath it.

Position in the build-up
Layer 3 of 3
Consumption
max. 0.25 l/m²
Suitability
Period-building facades, vapour-open

Interior insulation

PScoat ECI Interior

For application on interior walls when the exterior cannot be treated. Vapour-open, reflective, dirt- and mould-resistant. A water-based acrylic resin coating filled with microspheres.

Application
Interior walls, own build-up
Lambda value
0,000416
Sd value
0.11 at 1 mm
Order
0.3 mm replaces a minimum of 5 cm of polystyrene
Consumption
ca. 0,3 l/m²
System selection

Which system fits?

Three details are enough to work out the material required. Add the recommendation to the order below with a single click.

Desired insulation level

This requirement is a guide value for a smooth substrate. Texture, absorbency and application method change it; it only becomes binding once tested on a sample area on the original substrate.

Facade packages

Four packages, four insulation goals

Which package fits depends on what the building needs to achieve. The first three include the material for the complete build-up; the fourth also includes application by a specialist contractor. With a U-value guarantee on every package.

A residential building whose left half is rendered as a thermos flask — the coating keeps the warmth inside the building instead of making the wall thicker.

Orderable from 1 m² per package. Orders below 50 m² are dispatched from the Ketsch warehouse: shipping abroad from €97, with an additional €18 decanting fee if the order is not an exact multiple of 18 m². You can see the exact shipping costs for your country in the cart. Prices per square metre of facade, including VAT. The first three packages cover the material without application; PScoat Komplett includes application by a specialist contractor and is billed after measurement. The U-values apply to the respective system build-up; we provide a U-value guarantee on every package.

Enquire about a build-up for your property

Energy-saving guarantee

You don't have to
just take our word for it.

The thermal effect of PScoat has been studied under controlled conditions and on real buildings. That's why we go one step further: we tie our performance to a measurable result on the treated component.

What matters isn't what we promise.

What matters is what's actually achieved on your building. The energy-saving guarantee reduces your risk and makes the promised thermal effect verifiable.

01

Your building

We look at the starting situation and the existing wall structure. What always matters is the specific component – not a theoretical sample structure.

02

Apply PScoat

The coating is applied according to the chosen system and its intended use.

03

Verify the result

On request, the thermal effect can be verified through a documented U-value measurement on the specific component.

No blind trust.
A verifiable result.
Important:
The guarantee relates to the promised thermal effect of the treated external wall. Individual heating behaviour, ventilation habits or leaks in the building envelope are independent of this.
Available individually

Individual Products

All PScoat components are also available individually in containers – for trade businesses, reorders and touch-ups.